ALTA WIRELESS AIR VELOCITY / SPEED SENSOR
C$ 563.32
Part#
MNS2-9-W2-PS-AV-LPO
Region | Frequency
Canada - 900 MHz
Product Variations
Add to Cart Successfully! CHECK OUT to view cart, manage quantity and pay.
Product Description
Description
The ALTA wireless air speed sensor measures the pressure difference between two input ports, the temperature, and altitude determines the speed at which the air is moving in a system and transmits the measurement to iMonnit. The sensor measures the pressure difference between two ports. When viewing the sensor from the top, the right inlet port is the negative or low side pressure input. When the pressure on this port is greater than the left port the sensor produces a negative pressure reading. When the pressure is greater on the left port the sensor produces a positive pressure reading. Combined with the temperature and the altitude, the sensor determines at what rate the air is flowing in a system.Features
In the Box
- Power Supply
- USB Cable
- Wireless Sensor
- Mounting Hardware
- 2 x AA Batteries
- AC Power Supply
Product Specifications
Pressure Range | -500 Pa to 500 Pa |
Allowable Overpressure | 100 kPa |
Rated Burst Pressure | 500 kPa |
Max Humidity for Long-Term Exposure | 40°C dew point |
Sensing Range | Range at 0 m Altitude: 0-30m/s Range at 5000 m Altitude: 0-40m/s Range at 8000 m Altitude: 0-50m/s |
Span Repeatability | 0.5% of reading |
Span Shift Due to Temperature Variation | < 0.5% of reading per 10°C |
Offset Stability | < 0.05 Pa/year |
Calibrated For | Air, N2 |
Media Compatibility | Air, N2, O2, non-condensing |
Weight | 3.7 oz. |
Variation Specifications |
|
Supply Voltage | 2.7–3.8 VDC (3.0–3.8 VDC using power supply) |
ALTA AA Specifications |
|
Battery Type | 2 Replaceable AA 1.5 V Batteries |
Dimension | 4.375 in x 2.470 in x 1.12 in |
Supply Voltage | 2.0 – 3.8 V (2 x AA 1.5V Batteries or Optional Power Supply) |
Battery Life | At 1 hour heartbeat setting, included AA batteries will typically last 6-8 Years. ** |
Max Operating Temperature Using AA Alkaline | -18°C to 55°C (0°F to 130°F) |
Max Operating Temperature Using AA Lithium | -40°C to 60°C (-40°F to 140°F) |
Optimal Battery Operating Temperature | +10°C to +50°C (+50°F to +122°F) |
Enclosure Material | ABS |
ALTA 900 MHz Specifications |
|
Operating Frequency | 900 MHz Operating Frequency |
Certifications | Complies with Part 15 of the FCC Rules. (FCC ID: ZTL-G2SC1) Complies with Industry Canada standards. (IC: 9794A-G2SC1) |
Device Range | Device Range Up to 1,200 ft. non-line-of-sight, wireless device range* |
Security | Encrypt-RF® (Diffie-Hellman Key Exchange + AES-128 CBC) |
Documentation
Applications
Suggested Application Uses for This Sensor
- Building / Room Pressure
- Air Flow
- Variable Air Volume Filter Status
- Duct Pressure
- Clean Rooms
- Hospitals
- Fume Hoods
- Computer Rooms